src/c/i/cim-14.12/CDPSM/IEC61968/WiresExt.py   CIM(Download)
#------------------------------------------------------------------------------
 
from CDPSM.IEC61970.Core import ConductingEquipment
from CDPSM.IEC61970.Wires import ACLineSegment
from CDPSM.IEC61970.Core import IdentifiedObject
class DistributionTransformerWinding(ConductingEquipment):
    """ Conducting connection point of a distribution / unbalanced transformer winding instance. This class differs from Wires::TransformerWinding as follows: - the eight Pi model attributes are moved into separate class, that can be optionally referred to from several winding instances. - the three grounding attributes can differ per winding instance, even for windings that use the same TransformerInfo, so they are kept on DistributionTransformerWinding. 'sequenceNumber' attribute replaces 'windingType' attribute.  All the other attributes come from the WindingInfo (and its relationships). TransformerInfo is associated to the DistributionTransformer as referenceable data, so it can be defined once and referred to from instances, instead of being specified with each instance.Conducting connection point of a distribution / unbalanced transformer winding instance. This class differs from Wires::TransformerWinding as follows: - the eight Pi model attributes are moved into separate class, that can be optionally referred to from several winding instances. - the three grounding attributes can differ per winding instance, even for windings that use the same TransformerInfo, so they are kept on DistributionTransformerWinding. 'sequenceNumber' attribute replaces 'windingType' attribute.  All the other attributes come from the WindingInfo (and its relationships). TransformerInfo is associated to the DistributionTransformer as referenceable data, so it can be defined once and referred to from instances, instead of being specified with each instance.
    """
 
    #--------------------------------------------------------------------------

src/c/i/cim-14.12/CDPSM/IEC61970/Wires.py   CIM(Download)
#------------------------------------------------------------------------------
 
from CDPSM.IEC61970.Core import ConductingEquipment
from CDPSM.IEC61970.Core import PowerSystemResource
from CDPSM.IEC61970.Core import EquipmentContainer
class BusbarSection(ConductingEquipment):
    """ A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation.  Voltage measurements are typically obtained from VoltageTransformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal.A conductor, or group of conductors, with negligible impedance, that serve to connect other conducting equipment within a single substation.  Voltage measurements are typically obtained from VoltageTransformers that are connected to busbar sections. A bus bar section may have many physical terminals but for analysis is modelled with exactly one logical terminal.
    """
 
    #--------------------------------------------------------------------------
class ShuntCompensator(ConductingEquipment):
    """ A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor.  A negative value for reactivePerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device.  Ground is implied.A shunt capacitor or reactor or switchable bank of shunt capacitors or reactors. A section of a shunt compensator is an individual capacitor or reactor.  A negative value for reactivePerSection indicates that the compensator is a reactor. ShuntCompensator is a single terminal device.  Ground is implied.
    """
 
    #--------------------------------------------------------------------------
class Conductor(ConductingEquipment):
    """ Combination of conducting material with consistent electrical characteristics, building a single electrical system, used to carry current between points in the power system.Combination of conducting material with consistent electrical characteristics, building a single electrical system, used to carry current between points in the power system.
    """
 
    #--------------------------------------------------------------------------

src/c/i/cim-14.12/CDPSM/IEC61970/Wires.py   CIM(Download)
class Switch(ConductingEquipment):
    """ A generic device designed to close, or open, or both, one or more electric circuits.A generic device designed to close, or open, or both, one or more electric circuits.
    """
 
    #--------------------------------------------------------------------------

src/c/i/cim-14.12/CDPSM/IEC61970/Wires.py   CIM(Download)
class Junction(ConductingEquipment):
    """ A point where one or more conducting equipments are connected with zero resistance.A point where one or more conducting equipments are connected with zero resistance.
    """
 
    #--------------------------------------------------------------------------
class EnergySource(ConductingEquipment):
    """ A generic equivalent for an energy supplier on a transmission or distribution voltage level.A generic equivalent for an energy supplier on a transmission or distribution voltage level.
    """
 
    #--------------------------------------------------------------------------
class SynchronousMachine(ConductingEquipment):
    """ An electromechanical device that operates synchronously with the network. It is a single machine operating either as a generator or synchronous condenser or pump.An electromechanical device that operates synchronously with the network. It is a single machine operating either as a generator or synchronous condenser or pump.
    """
 
    #--------------------------------------------------------------------------
class EnergyConsumer(ConductingEquipment):